Air Leakage Testing

Also called: Air tightness test · Air pressure test · Blower door test

Accredited air tightness testing for new dwellings and commercial buildings, carried out to the ATTMA technical standards and reported quickly so it doesn't hold up your sign-off.

What is an air leakage test?

An air leakage test (also called an air tightness, air permeability or blower door test) measures how much air escapes through gaps in a building's envelope.

A calibrated fan is fitted into an external doorway and the building is pressurised and depressurised to 50 Pascals. The leakage rate is measured in m³/(h·m²) at 50 Pa: cubic metres of air per hour, per square metre of envelope. The lower the figure, the more airtight the building.

Photo: air leakage testing on one of your sites

What a result looks like

We measure airflow at a range of pressures, both pushing air in and pulling it out, and work out the leakage at 50 Pa. Your result is compared with the design target used in the SAP or SBEM calculation.

Example result

ATTMA TSL1

Two-storey detached house · single plot

Air permeability

3.21m³/(h·m²)
@ 50 Pa

Pass

Design target 5.00

60080010001200203040506070ΔP (Pa)
DepressurisationPressurisationFlow m³/h

Why it matters

Building Regulations Part L requires air permeability testing on new buildings, and the result feeds straight into the SAP or SBEM calculation. A better result can mean a better energy rating and lower running costs. A poor one can fail compliance.

Airtight buildings are also more comfortable, with fewer draughts.

Domestic and non-domestic

Domestic testing

Houses, flats and bungalows, including single plots, self-builds and multi-plot developments. On larger sites testing is usually done on a sample of plots, as set out in the regulations. We can advise on the sampling plan and which plots to test.

Non-domestic testing

Offices, schools, warehouses, retail units, care homes and other commercial buildings, including larger and more complex buildings. Add any maximum building size or volume you can test.

What's involved

  1. 1

    We discuss the project, the design air permeability target and the best time to test.

  2. 2

    We send a pre-test checklist to the site team: what needs to be sealed, finished and ready.

  3. 3

    On the day we set up and run the test. Where needed, we use smoke or other diagnostics to trace leaks.

  4. 4

    You get the result on site, and the certificate is issued within X working days.

What you receive

A test certificate and report suitable for Building Control and for use in your SAP or SBEM calculation.

FAQs

When should the test happen?

Once the building envelope is substantially complete, with all openings, seals and service penetrations finished. Ideally before final decoration, so any leaks can still be fixed easily.

What if we fail?

We help find the leakage paths, advise on remedial work and come back to retest. State your retest policy and cost.

How long does it take?

Typically X hours for a house, longer for large commercial buildings.

Do you test single dwellings?

Yes, including self-builds and extensions where required.

Can you test in the evening or at weekends?

Yes. If your test is urgent we can offer evening and weekend appointments.

Need a quote or have a question?

Send us your plans or tell us about your project and we'll come back with a clear quote.

Book an air test
Call usGet a quote